Makroblend® KU2-7912/4

(PC+PBT) blend; impact modified; high toughness at low temperatures; unreinforced

Brand
Makroblend
Available in
Europe Middle-East and Africa, Latin America, North America, Asia Pacific

Typical values

PropertyValueUnitTest methodCondition
Thermal properties
Temperature of Deflection under Load (HDT)82°CISO 75-1,-21.80 MPa
Temperature of Deflection under Load (HDT)106°CISO 75-1,-20.45 MPa
Vicat Softening Temperature120°CISO 30650 N; 120 °C/h
Melting Temperature223°CISO 11357-1,-310 °C/min
Coefficient of Linear Thermal Expansion (CLTE), parallel0.910⁻⁴/KISO 11359-1,-223 to 55 °C
Coefficient of Linear Thermal Expansion (CLTE), normal0.910⁻⁴/KISO 11359-1,-223 to 55 °C
Burning BehaviorHBUL 941.6 mm
Burning Rate (FMVSS-302)PASSEDISO 3795≥ 1.0 mm
Oxygen Index21%ISO 4589-2Method A
Thermal Conductivity, through-plane0.2W/(m·K)ISO 830223 °C; 50 % r. h.
Glow Wire Test (GWFI)700°CIEC 60695-2-122.0 mm
Rheological properties
Melt Volume-flow Rate (MVR)16cm³/10 minISO 1133-1260 °C/5 kg
Molding Shrinkage, parallel/normal0.7 – 0.9%b. o. ISO 2577Value range based on general practical experience; 600 bar
Post-Molding Shrinkage, parallel/normal0.1 – 0.2%b. o. ISO 2577Value range based on general practical experience; 1 h 90 °C
Göttfert Melt Viscosity670Pa·sBayer test260 °C; 165 s⁻¹
Mechanical properties (23 °C; 50 % r. h.)
Tensile Modulus2050MPaISO 527-1,-21 mm/min
Yield Stress50MPaISO 527-1,-250 mm/min
Yield Strain4%ISO 527-1,-250 mm/min
Stress at Break45MPaISO 527-1,-250 mm/min
Nominal Strain at Break≥ 50%ISO 527-1,-250 mm/min
Flexural Modulus2100MPaISO 1782 mm/min
Flexural Strength75MPaISO 1782 mm/min
Flexural Stress at 3.5 % Flexural Strain66MPaISO 1782 mm/min
Flexural Strain at Flexural Strength5.5%ISO 1782 mm/min
Izod Notched Impact Strength60kJ/m²ISO 180/A23 °C
Izod Notched Impact Strength52kJ/m²ISO 180/A-20 °C
Izod Notched Impact Strength45kJ/m²ISO 180/A-30 °C
Charpy Notched Impact Strength60kJ/m²ISO 179-1/1eA23 °C
Charpy Notched Impact Strength45kJ/m²ISO 179-1/1eA-30 °C
Ball Indentation Hardness100N/mm²ISO 2039-1358 N
Other properties (23 °C)
Water Absorption (Saturation Value)0.6%ISO 62Water at 23 °C
Water Absorption (Equilibrium Value)0.2%ISO 6223 °C; 50 % r. h.
Density1200kg/m³ISO 1183-1
Bulk Density700kg/m³ISO 60Pellets
Electrical properties (23 °C; 50 % r. h.)
Relative Permittivity3.2IEC 60250100 Hz
Relative Permittivity3.1IEC 602501 MHz
Dielectric Dissipation Factor1510⁻⁴IEC 60250100 Hz
Dielectric Dissipation Factor13010⁻⁴IEC 602501 MHz
Volume Resistivity1.00E+15Ω·mIEC 62631-3-1
Surface Resistivity1.00E+17ΩIEC 62631-3-2
Electric Strength35kV/mmIEC 60243-11 mm
Comparative Tracking Index (CTI)500VIEC 60112Solution A
Comparative Tracking Index (CTI M)100IEC 60112Solution B
Electrolytic CorrosionA1IEC 60426
Processing conditions for test specimens
Injection Molding - Melt Temperature260°CISO 294-1
Injection Molding - Mold Temperature70°CISO 294-1
Injection Molding - Injection Velocity200mm/sISO 294-1
Recommended processing and drying conditions
Dry Air Drying Temperature105°C
Dry Air Drying Time2 – 4h
Moisture Content max. (%)0 – 0.02%
Melt Temperatures250 – 270°C
Standard Melt Temperature260°C
Barrel Temperatures230 – 240°CRear
Barrel Temperatures240 – 250°CMiddle
Barrel Temperatures250 – 260°CFront
Barrel Temperatures260 – 270°CNozzle
Mold Temperatures60 – 80°C
Hold Pressure (% of Injection Pressure)50 – 75%
Plastic Back Pressure (specific)50 – 100bar
Peripheral Screw Speed0.1 – 0.2m/s
Shot-to-Cylinder Size30 – 70%
Vent Depth0.025 – 0.075mm

Documents

  • Technical Data Sheet
  • Safety Data Sheet
  • Viskosität Schergeschwindigkeit
  • Secant modulus - Strain
  • Viscosity Shear Rate
  • Spannung-Dehnung
  • Specific Volume-Temperature (pvT)
  • Spezifisches Volumen-Temperatur (pvT)
  • Sekantenmodul-Dehnung
  • Stress-Strain

EU-CLP

Hazard Classes / Hazard Categories

According to Regulation (EC) No 1272/2008 on classification, labelling

and packaging of substances and mixtures (the 'CLP Regulation')

No classification in accordance with the Regulation (EC) No. 1272/2008.

GB-CLP

Hazardous classification under EU-CLP is not yet available; therefore, the product is not yet placed on the market within the EU-REACh regulatory area.