Makroblend® EL700

(PC+PET) blend; impact modified; flame-retardant; unreinforced; good impact strength; dimensional stability and chemical resistance

Brand
Makroblend
Available in
Latin America, North America, Asia Pacific, Europe Middle-East and Africa

Typical values

PropertyValueUnitTest methodCondition
Thermal properties
Temperature of Deflection under Load (HDT)123°CISO 75-1,-20.45 MPa
Temperature of Deflection under Load (HDT)100°CISO 75-1,-21.80 MPa
Vicat Softening Temperature136°CISO 30650 N; 120 °C/h
Coefficient of Linear Thermal Expansion (CLTE), parallel0.810⁻⁴/KISO 11359-1,-223 to 55 °C
Coefficient of Linear Thermal Expansion (CLTE), normal0.910⁻⁴/KISO 11359-1,-223 to 55 °C
Burning Behavior5VAUL 943.0 mm
Burning BehaviorV-0UL 941.5 mm
Thermal Conductivity, through-plane0.2W/(m·K)ISO 830223 °C; 50 % r. h.
Rheological properties
Melt Volume-flow Rate (MVR)15cm³/10 minISO 1133-1270 °C/5 kg
Molding Shrinkage, parallel/normal0.6 – 0.8%b. o. ISO 2577Value range based on general practical experience; 600 bar
Mechanical properties (23 °C; 50 % r. h.)
Tensile Modulus2350MPaISO 527-1,-21 mm/min
Yield Stress58MPaISO 527-1,-250 mm/min
Yield Strain4.5%ISO 527-1,-250 mm/min
Stress at Break57MPaISO 527-1,-250 mm/min
Nominal Strain at Break100%ISO 527-1,-250 mm/min
Flexural Modulus2300MPaISO 1782 mm/min
Flexural Strength86MPaISO 1782 mm/min
Flexural Stress at 3.5 % Flexural Strain72MPaISO 1782 mm/min
Izod Notched Impact Strength60kJ/m²ISO 180/A23 °C
Izod Notched Impact Strength30kJ/m²ISO 180/A-30 °C
Charpy Notched Impact Strength30kJ/m²ISO 179-1/1eA-30 °C
Charpy Notched Impact Strength65kJ/m²ISO 179-1/1eA23 °C
Puncture Impact Behavior - Maximum Force5200NISO 6603-2-30 °C
Puncture Impact Behavior - Maximum Force4100NISO 6603-223 °C
Puncture Impact Behavior - Puncture Energy50JISO 6603-2-30 °C
Puncture Impact Behavior - Puncture Energy45JISO 6603-223 °C
Other properties (23 °C)
Water Absorption (Saturation Value)0.5%ISO 62Water at 23 °C
Water Absorption (Equilibrium Value)0.2%ISO 6223 °C; 50 % r. h.
Density1280kg/m³ISO 1183-1
Electrical properties (23 °C; 50 % r. h.)
Relative Permittivity3IEC 602501 MHz
Relative Permittivity3.1IEC 60250100 Hz
Dielectric Dissipation Factor13010⁻⁴IEC 602501 MHz
Dielectric Dissipation Factor2010⁻⁴IEC 60250100 Hz
Volume Resistivity1.00E+14Ω·mIEC 62631-3-1
Surface Resistivity1.00E+16ΩIEC 62631-3-2
Electric Strength34kV/mmIEC 60243-11 mm
Comparative Tracking Index (CTI)225VIEC 60112Solution A
Processing conditions for test specimens
Injection Molding - Melt Temperature270°CISO 294-1
Injection Molding - Mold Temperature70°CISO 294-1
Injection Molding - Injection Velocity200mm/sISO 294-1
Recommended processing and drying conditions
Dry Air Drying Temperature110°C
Dry Air Drying Time2 – 4h
Moisture Content max. (%)0 – 0.01%
Melt Temperatures260 – 280°C
Standard Melt Temperature270°C
Barrel Temperatures255 – 270°CNozzle
Barrel Temperatures255 – 265°CFront
Barrel Temperatures250 – 260°CMiddle
Barrel Temperatures245 – 255°CRear
Mold Temperatures50 – 100°C
Hold Pressure (% of Injection Pressure)50 – 75%
Plastic Back Pressure (specific)50 – 150bar
Peripheral Screw Speed0.05 – 0.2m/s
Shot-to-Cylinder Size30 – 70%
Vent Depth0.025 – 0.075mm

Documents

  • Technical Data Sheet
  • Safety Data Sheet

EU-CLP

Hazard Classes / Hazard Categories

According to Regulation (EC) No 1272/2008 on classification, labelling

and packaging of substances and mixtures (the 'CLP Regulation')

No classification in accordance with the Regulation (EC) No. 1272/2008.

GB-CLP

Hazardous classification under EU-CLP is not yet available; therefore, the product is not yet placed on the market within the EU-REACh regulatory area.